PRSO20261015


You will only be able to view fees or schedule inspections or view conditions if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRSO20261015
Solar
Issued
Addition
Install a 7.920 kW DC grid-tied rooftop solar PV system with 18 modules; no roof sheathing replacement and no structural change. Install one 13.5 kWh Tesla Powerwall 3 with one Tesla Gateway 3 to back up a 200 A main panel; no structural change. Provide code-compliant installation of customer-supplied EV charging equipment; no structural change. Replace existing meter can and service entrance cable with new conduit and 4/0 200 A SER conductors, coordinating utility disconnect/reconnect; no structural change.
09/14/2026
10/08/2026
05/05/2027

Locations

Property
00-00-31-1401-007A-0162

Structure
# 46321, SFR CUST

Address
1731 N FLETCHER AV, FERNANDINA BEACH, FL 32034

Permits

Permit Number: PRSO20261015-BD1

Building
Issued
10/06/2026
05/05/2027

There are no submittals for this permit application.

Permit Number: PRSO20261015-EL1

Electrical
In Progress
05/05/2027

There are no submittals for this permit application.